Fine-wire construction
Braided copper accommodates movement between connection points. Specify conductor area, wire diameter and braid geometry.
DUCHUANGCABLE SYSTEMS · SINCE 2013FLEXIBLE CONDUCTORS
Fine copper wires form a flexible conductor for bonding and electrical connections. Braid can be supplied as strip or as a finished connection with terminal pads.
Enquire about this productPRODUCT OVERVIEW
Braided copper accommodates movement between connection points. Specify conductor area, wire diameter and braid geometry.
Finished straps require controlled pad dimensions, hole patterns and joint preparation. Define loose braid or a complete terminated connection.
Current capacity depends on joints, ventilation, duty and the full assembly. A dimensional table alone does not establish an installed current rating.
No. Width and thickness describe the braid envelope; conductor cross-section describes the copper area. Confirm both together with terminal geometry.
Send the drawing or sample, required material, dimensions, quantity and installation conditions. We confirm the quotation, sample and applicable documentation before production.
APPLICATIONS
Electrical bonding, switchgear, equipment connections and flexible earthing assemblies.
SELECTION
Specify conductor cross-section, finish, free length, terminal geometry, hole pattern and insulation. Installed current capacity depends on the complete assembly and operating conditions.
DIMENSIONAL SELECTION
| Conductor area (mm²) | Width × thickness (mm) | Wire diameter (mm) | Enquiry |
|---|---|---|---|
| 3 | 5 x 1 | 0.15 | Select size |
| 40 | 25 x 2.5 | 0.15 | Select size |
| 50 | 28 x 3 | 0.15 | Select size |
| 60 | 30 x 3 | 0.15 | Select size |
| 70 | 30 x 3.5 | 0.15 | Select size |
| 75 | 30 x 4 | 0.15 | Select size |
| 100 | 40 x 4 | 0.15 | Select size |
FTCB 15 dimensional reference from nVent ERIFLEX; describes braid material, not a tested finished Duchuang assembly. Values are selection references, not a declaration of interchangeability. Confirm the quoted product and approved drawing before ordering.
ALSO IN THIS FAMILY
CONSTRUCTION & DIMENSIONS
Choose the construction that matches your application. Final dimensions and tolerances are confirmed for the selected product.
ENGINEERING DETAILS
L = hole-centre length; W = braid width; d = terminal-hole diameter. Lug type, conductor area and finish are specified with the assembly.
ENGINEERING DETAILS
Select pattern a–h or k. W and W1/L1 describe the pad envelope; L2–L5 identify the indicated pitches; d is hole diameter. All values require an approved assembly drawing.